Product Improvement Notice
- Tuesday, 04 January 2022 17:21
Product Improvement Notice: Wiring Compartment & Lugs
Rex Power Magnetics has updated and improved the configuration of terminals and standard lugs. The most notable change is on our 3 phase 30, 45 and 75 kVA, however small improvements are on other ratings as well.
Our new standard specification for lugs will ensure that lugs are appropriately sized for the larger aluminum cables that have become more commonly utilized. (See table below)
On 30, 45, and 75 kVA models, primary and secondary terminals are split: Primary at the top-front, and Secondary at the bottom-front. This allows neater cable organization and better accommodation for the bending radius of larger cables.
Transformers ship with suitably sized mechanical Cu-Al lugs and hardware for cable connection, or suitably sized and cleaned terminal pads with the appropriate NEMA hole pattern.
Standard units include:
- 3-phase isolation transformers up to 300 kVA, with 600 V or 480 V primary, 208Y/120 V secondary
- 1-phase isolation transformers up to 100 kVA that have a 600 V or 480 V primary, 240/120 V secondaryr new standard specification for lugs will ensure that lugs are appropriately sized for the larger aluminum cables that have become more commonly utilized.
For all other Isolation Transformers, Drive Isolation Transformers, Encapsulated Transformers, etc., Rex engineering will defer to the last column to determine the lugs to be supplied. Of course, optional lug kits may be specified and included.
Rex Power Magnetics remains committed to continual product improvement, driven by openness to feedback from the specifying engineering community, electrical contractors, OEMs and integrators, electricians, and facility maintenance personnel. If you have any feedback, please write directly to engineering@rexpowermagnetics.com
The Rex Power Magnetics website makes available drawings for convenient reference to many of the most commonly ordered transformers. All of the drawings affected by this change have been updated to reflect the updated lug table.
More Articles...
- Updated catalogs and guide specs
- Upcoming Changes to enclosure sizes (2)
- Dry Type Transformer Minimum Efficiency Rules (Canada)
- NRCAN 2019 AND ONTARIO GREEN ACT
- About NRCan 2018 ENERGY EFFICIENCY REQUIREMENTS IN ONTARIO (updated 12/21/2017)
- 2018 Price Adjustment
- CLOSURE IN MANUFACTURING
- CSA & UL both “Qualify” Rex Power Magnetics as Test Facility
- REX Cast Coil Transformers now UL Marked
- Rex Power Magnetics among Canada's 50 BEST MANAGED COMPANIES for the 3rd Consecutive Year